@article{Harjanto_Hani Rumawan_Suprihanto_Haviluddin_Bekti Nurdianto_2022, place={Purwokerto}, title={A CHARACTERISTICS OF LINEARITY AND SENSITIVITY IN MEASURING THE MQ-4 SENSOR ON GAS LINE LEAKAGE}, volume={3}, url={http://jutif.if.unsoed.ac.id/index.php/jurnal/article/view/229}, DOI={10.20884/1.jutif.2022.3.2.229}, abstractNote={<p><em>A natural gas utilization with a domestic house-gas pipeline is essential. However, the house-gas installation pipe can cause a dangerous leak, so the house-gas leak detector is requires. This study aims to build and analyze a leak detector for natural gas flow on the stove using the MQ-4 gas sensor based on the house-gas linearity and sensitivity characteristics levels in the air with a threshold of 1000 ppm. Based on experimental, the sensor linearity value for the detected house-gas has been obtained in a correlation coefficient of 0.99 which indicates the sensor is quite sensitive in order to the house-gas detected. Then, the sensor sensitivity value has been acquired with the regression equation Y=-0.00449+(0.000481)X which means the voltage value at 0 ppm is around -0.00449 volts and increase at each ppm are 0.000481 volts with a value of 0.000481 volts with the effectiveness of the tools reaches 100%. Therefore, the study shown that the detection tools and systems can work properly.</em></p&gt;}, number={2}, journal={Jurnal Teknik Informatika (Jutif)}, author={Harjanto, Arif and Hani Rumawan, Fatkhul and Suprihanto, Didit and Haviluddin, Haviluddin and Bekti Nurdianto, Bangkit}, year={2022}, month={Apr.}, pages={287-294} }